Products
PRODUCTS DETAILS
Home > Products >
1nm - 3000µm Nano Laser Particle Size Analyzer Laser Granulometry Laser Diffraction LPA-197W

1nm - 3000µm Nano Laser Particle Size Analyzer Laser Granulometry Laser Diffraction LPA-197W

MOQ: 1 set
Price: Negotiable
Standard Packaging: Plywood packing
Delivery Period: 5~8 working days
Payment Method: L/C,T/T
Supply Capacity: 500 sets/month
Detail Information
Place of Origin
China
Brand Name
SHUOBODA
Certification
ISO/CE
Model Number
LPA-197W
Measuring Range:
1nm~10000nm (related To The Sample)
Measuring Time:
2-5 Minutes
Measuring Principle:
Principle Of Dynamic Photon Correlation Spectroscopy.
Number Of Channels:
64-4000
Delay Time:
Delay Time 20ns-100ms
Accuracy/repeatability Error:
≤1% (national Standard Material D50 Deviation)
Highlight:

3000µm Laser Granulometry Particle Size Analyzer

,

1nm Laser Granulometry Particle Size Analyzer

,

Laser Nano Particle Size Analyzer

Product Description

LPA-197W Wide Range Nano Laser particle size analyzer, Laser Granulometry, Laser Diffraction, 1nm-3000µm

Product Introduction

The LPA-197W wide-range laser particle size analyzer is based on the principles of photon correlation spectroscopy and full-range Mie scattering. It can test both nanometer-level and micrometer-level powder particle size distribution. The operating software can quickly switch between nanometer and micrometer test programs. It only takes 2 to 5 minutes to test each sample, and the test is fully automatic and continuous under computer control. It also has dynamic light concentration test function and static light molecular weight detection function, which can quickly and qualitatively test the concentration of the solution.

 

Using ultrasonic anti-dry burning technology, the sample cell will automatically turn off the ultrasonic power supply in the waterless state, intelligent module design, humanized operation software, and quickly obtain accurate and reliable particle size results. Built-in photoelectronics, sample cell, circulation system, etc., so that the sample flows in the pipeline for a short time, avoiding stratification and re-agglomeration after sample dispersion, and the repeatability and stability reach the measurement level of similar foreign instruments.

 

Adopting a fully sealed metal frame, it has strong anti-electromagnetic interference ability; multi-system integrated design, it has the advantages of wide range, good repeatability, high precision, high degree of automation, and fast test speed. It can be tested automatically and continuously, and the results are automatically recorded and saved by the computer. It is very suitable for enterprises and scientific research institutions with a wide range of products and a wide distribution range. It is a domestically produced, cost-effective, fully automatic laser particle size analyzer that is widely praised by customers.

 

Application Fields

Various metal powders: such as lead powder, aluminum powder, molybdenum powder, magnesium powder, tungsten powder, copper powder, alloy powder, etc.

Various non-metallic powders: such as calcium carbonate, talc, kaolin, graphite, wollastonite, brucite, mica powder, silicon dioxide, zirconium oxide, zinc oxide, magnesium oxide, etc.

Other powders: such as catalysts, abrasives, cement, medicines, pesticides, building materials, food, coatings, dyes, sediment, ceramics, chemical materials and various emulsion particles.

Technical specifications

Nano-segment indicators parameters

Measuring range

1nm10000nm (related to the sample)

Measuring time

2-5 minutes

Measuring principle

Principle of dynamic photon correlation spectroscopy.

Number of channels

64-4000

Delay time

Delay time 20ns-100ms

Accuracy/repeatability error

1% (national standard material D50 deviation)

Concentration test

Quickly test the mass concentration and relative concentration of nano-samples

Test concentration range

Select different test gears according to the concentration of the test sample (1-10 gears, from concentrated to diluted)

Optical path system

High gain low noise photomultiplier tube, dual light source channel

Micron segment parameters

Measuring range

0.01µm3000µm

Test time

1-2 minutes (related to sample characteristics)

Measurement principle

Full range Mie scattering principle

Accuracy/repeatability error

1% (national standard material D50 deviation)

Detector

128-level multi-element detector

Signal light source

Imported semiconductor laser

Laser life

More than 70,000 hours

Optical path system

Inverted Fourier optical system

Other parameters

Test method

Wet cycle sampling test, automatically determine parameters such as the number of channels and the most delayed time, with two modes: monodisperse and polydisperse.

Automatic test

Automatic water absorption, automatic centering, automatic cleaning of sample cell and circulation pipeline

Test medium

Pure water, distilled water or ethanol, etc.

Sample cell

500mL standard sample cell, circulation test; 2.5 mL fixed sample cell, static test

Dispersion method

Sample cell and 60w ultrasonic disperser, agitator combined, ultrasonic dispersion

Instrument size/weight

880*410*500(mm)/70KG

Working power supply

AC220V ±22V 50Hz ±0.5Hz:

 

Instrument Advantages

1. It has functions such as automatic water absorption, automatic centering, automatic testing, automatic cleaning, water level monitoring, and ultrasonic anti-dry burning.

 

2. Built-in automatic water suction pump, which can automatically fill water without manual operation. A water level detector is installed above the sample cell. When the water level reaches the specified height, the electromagnetic valve is closed to ensure the accuracy of each test medium.

 

3. When the sample is added, the large-diameter ultrasonic dispersion cell and the agitator work simultaneously to ensure that the sample is quickly and evenly dispersed. The peristaltic pump circulation pipelines are all equal-section and equal-flow, without centrifugal negative pressure areas, easy to clean, no bubbles during transportation, and short-distance circulation, which effectively avoids sample agglomeration and ensures the accuracy and repeatability of the test.

 

4. There are two sampling systems for dynamic circulation and static fixed testing. The static fixed test uses high-quality high-optical glass, and a 2.5 mL thin slit detection cell is customized for precious samples. The sample is directly recovered after the test.

 

Software

1. The test time is 2 to 5 minutes, and it can be tested single or multiple times continuously.

 

2. With a proprietary polydisperse analysis algorithm, it can quickly analyze polydisperse and monodisperse particle systems, test the mass concentration and relative concentration of nano samples, and directly test the sample temperature in real time, avoiding the measurement error caused by the temperature gradient of the sample cell and the constant temperature system.

 

3. The analysis software is compatible with Windows XP/Win7/Win10 systems.

 

4. Tables and graphs of 108-level particle sizes, volume distribution and number distribution modes. It provides data such as cumulative distribution, frequency distribution, cumulative 10%, 50%, 90%, 97%, average particle size and specific surface area to fully characterize the particle size characteristics of the sample.

 

5. The software operation interface can be selected in Chinese or English as needed, and the output results can be directly printed or converted to PDF and text files for storage.


R&D Laboratory

1nm - 3000µm Nano Laser Particle Size Analyzer Laser Granulometry Laser Diffraction LPA-197W 01nm - 3000µm Nano Laser Particle Size Analyzer Laser Granulometry Laser Diffraction LPA-197W 1

  

 

sitemap |  Privacy Policy | China Good Quality Lab Test Instrument Supplier. Copyright © 2025 Shuoboda Instruments (Hunan) Co., Ltd. . All Rights Reserved.