Products
PRODUCTS DETAILS
Home > Products >
AAS-4510 AAS Atomic Absorption Spectrophotometer 190nm - 900nm

AAS-4510 AAS Atomic Absorption Spectrophotometer 190nm - 900nm

MOQ: 1 set
Price: Negotiable
Standard Packaging: Plywood packing
Delivery Period: 5~8 working days
Payment Method: L/C,T/T
Supply Capacity: 500 sets/month
Detail Information
Place of Origin
China
Brand Name
SHUOBODA
Certification
ISO/CE
Model Number
AAS-4510
Wavelength Range:
190nm ~ 900nm
Wavelength Indication Error:
±0.3nm
Wavelength Repeatability:
≤ 0.15nm
Absorbance Range:
-0.1~2.5(A)
Spectral Bandwidth:
0.1nm, 0.2nm, 0.4nm, 1.0nm, 4 Levels Adjustable
Baseline Stability:
≤ 0.005 A/30min (Cu)
Highlight:

AAS Atomic Absorption Spectrophotometer 190nm-900nm

,

Atomic Absorption Spectrometer with wide wavelength range

,

AAS-4510 spectrophotometer for precise elemental analysis

Product Description
AAS-4510 Atomic Absorption Spectrophotometer
AAS-4510 AAS Atomic Absorption Spectrophotometer 190nm - 900nm 0
The AAS-4510 atomic absorption spectrophotometer is a highly automated instrument completely controlled by PC, capable of flexible configuration with flame and graphite furnace atomizers. Featuring unique optical mechanical design, safe flame system, advanced graphite furnace temperature control technology, optional background correction, and comprehensive workstation functions, this system adapts to your automated measurement requirements.
Key Features
  • Compact and elegant design
  • Convenient background subtraction method selection
  • Unique optical system design
  • Complete automated control via software workstation
  • Advanced graphite furnace temperature control technology
  • Safe, reliable, and convenient flame system
  • Multi-functional software workstation
  • Easy conversion between flame and graphite furnace systems
Flame System Specifications
Acetylene Air Flame Burner Head 100mm
Spray Chamber Polypropylene coating
Characteristic Concentration (Cu) ≤ 0.02μg/ml/1%
Measurement Repeatability ≤ 0.5%
Detection Limit (Cu) ≤ 0.006μg/ml
Safety System Automatic gas cutoff for insufficient pressure, power interruption, flameout, or burner mismatch
Technical Specifications
Optical System Rotating 4-lamp turret
Wavelength Range 190nm - 900nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ≤ 0.15nm
Absorbance Range -0.1 - 2.5(A)
Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm (4 levels adjustable)
Baseline Stability (Cu) ≤ 0.005 A/30min
D2 Background Correction ≥50 times correction capability at 1A background signal
Background Correction Method Self-absorbing background subtraction
Power Supply AC220V±22V 50Hz±1Hz
Atomic Absorption Graphite Furnace Control System
AAS-4510 AAS Atomic Absorption Spectrophotometer 190nm - 900nm 1
The graphite furnace control system enables flameless heating for atomic absorption analysis, serving as essential equipment for AAS-4530F and AAS-4510F atomic absorption spectrophotometers. This specialized instrument measures trace metal elements by injecting samples into a graphite tube. Under inert gas protection, samples undergo multiple temperature stages: drying to remove moisture, ashing to eliminate matrix interference without losing target elements, atomization to fully atomize elements for sensitive measurement, and high-temperature cleaning to remove residual samples.
Graphite Furnace Parameters
Heating Steps 20 steps
Temperature Range 20℃ - 3000℃
Slope Heating Time 0s - 999s
Maintain Heating Time 1s - 999s
Characteristic Amount (Cu) ≤1×10⁻¹¹ g
Measurement Repeatability (Cu) ≤3%
Detection Limit (Cd) ≤1.0×10 g
Inert Gas Requirement Argon (purity ≥99.99%), inlet pressure 0.3MPa
Cooling Water Tap water or circulating water, flow rate ≥2L/min
Display Interface Host workstation graphite furnace interface
Safety Features Gas pressure under-pressure alarm and furnace overheating alarm
Communication Interface RS-232 for host communication
Heating Capabilities High-power heating (1500℃-3000℃) and manual heating (1000℃-3000℃)
Power Requirements 220V±22V, 30A, 50Hz, approximately 5000W at 2700℃
Dimensions 280mm × 550mm × 420mm
Net Weight 60kg
Optional Accessories
  • Graphite furnace system
  • Graphite furnace autosampler
  • Cooling water circulation system
  • Hydride generator
  • Hollow cathode lamps for various elements
Software Workstation
The versatile software workstation supports Windows 7/XP/2000/NT operating systems. Featuring Chinese interface display for easy operation, rich menu content for enhanced application flexibility, convenient menu transitions, multiple analysis and calibration methods, default parameter settings for beginners, flexible storage/editing/printing options, and practical online help for timely problem resolution.
sitemap |  Privacy Policy | China Good Quality Lab Test Instrument Supplier. Copyright © 2025 Shuoboda Instruments (Hunan) Co., Ltd. . All Rights Reserved.