| MOQ: | 1 set |
| Price: | Negotiable |
| Standard Packaging: | Plywood packing |
| Delivery Period: | 5~8 working days |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 500 sets/month |
FSP-97/F97pro fluorescent spectrophotometer is a new generation of high-performance molecular luminescence analysis instrument. The product structure is exquisite, has the characteristics of high detection sensitivity, fast scanning speed, wide spectrum measuring range, high dynamic range, fast 3D scanning, and so on. Easily meet the requirements in the field of material research, pharmaceutical analysis, biochemical and clinical testing, water quality analysis and control, food safety testing (dairy products, aquatic products, such as vitamin C, selenium, aflatoxin), and other areas.
Instrument introduction:
FSP-97 series fluorescence spectrophotometer (FSP-97, FSP-97Pro, FSP-97XP) is a high-end fluorescence spectrophotometer product carefully developed by Xiangyi Instruments. The product adopts dual monochromator, proportional double optical path design with excitation light monitoring system, 150W Hamamatsu high quality xenon lamp, 1200 line/mm concave grating and large aperture aspheric mirror spectroscopic system. It is small in size, compact in structure and has detection. High sensitivity, fast scanning speed, wide spectral measurement range, large detection dynamic range and fast 3D scanning. Excellent mechanical structure and digital signal processing ensure that the instrument can complete 3D full-spectrum scanning in 1 minute during high-speed 3D scanning.
The new, professional, and user-friendly software design includes a variety of analysis capabilities. At the same time, the rich accessories greatly expand the application range of the instrument, and can support the measurement of liquid, powder and film samples. It can measure high-concentration samples with fluorescence quenching, and can accurately measure small samples as small as 5μl. Equipped with an automatic sample introduction system.
Usage:
FSP-97 series fluorescence spectrophotometer (FSP-97, FSP-97Pro, FSP-97XP) easily meets materials research, drug analysis, biochemical and clinical testing, water quality analysis control, food safety testing (vitamin C-GB5413.18-2010, selenium-GB5009.93- 2010, aflatoxin - GB5413.37-2010, benzo (a) - GB / T5009.27-2003, etc.) qualitative and quantitative analysis needs. It is your choice for multi-function, high-precision, high-efficiency fluorescence analysis!
Features:
1. High detection sensitivity: The Raman peak signal-to-noise ratio of the distilled water at 350nm in the F97PRO fluorescence spectrophotometer can reach ≥150 (P/P).
2. High scanning speed: The instrument adopts high-speed digital signal processing technology, and the scanning speed is up to 48000nm/min, reaching the world advanced level. The classic fluorescence spectrum can be obtained in 1 second, and high-quality 3D map scanning can be obtained in 1 minute, which is convenient for obtaining the fluorescent fingerprint information of the sample quickly.
3. New software analysis function: The new, professional and user-friendly software design includes a variety of analysis functions, enabling the instrument to perform analysis and test functions on samples under various conditions.
4. The structure of the instrument is exquisite: the small size and volume of the instrument are less than half of the domestic equivalent model products, breaking through the large and heavy product set of the traditional high-end fluorescence spectrophotometer, effectively saving laboratory space.
5. Excitation light path monitoring system: The instrument uses excitation light source monitoring technology to ensure that the instrument obtains a highly stable fluorescent signal.
6. Spectral bandwidth is multi-stage optional: the instrument excitation spectrum bandwidth and emission spectrum bandwidth are 2/5/10/20nm four-speed bandwidth.
7. High quality assurance: The instrument adopts high-quality Japanese Aachen original device for key components such as long-life de-ozone-type xenon lamp source and photomultiplier tube detector. Ensure that the instrument provides sufficient light intensity signal and detection sensitivity in the spectral range from 200nm to 900nm.
8. Spectral correction function: The spectral correction function can correct the spectral response function of the instrument itself to obtain the true fluorescence spectrum data of the sample.
9. Built-in automatic light door: shortens the sample's excitation time and protects samples that are easily photoreactive. Designed for samples that are prone to photoreaction or unstable fluorescence signals, the fluorescence analysis accuracy is improved by uniformly exciting the detection rhythm.
10. The detection dynamic range is large: the instrument fluorescence photometric value display range is 0.00-10000, and the large detection dynamic range makes the instrument more able to meet various analysis and testing requirements.
11. Supports a variety of measurement accessories: including single-hole sample cell holder, multi-purpose fluorescent sample holder, 200μL microcentrifuge tube measurement accessories, capillary micro sample measurement accessories, fluorescent sample semi-automatic injection accessories, single-hole sample cell adapter, membrane samples and Powder sample measurement accessories and jacketed sample cell holders. A wide range of accessories greatly expands the range of applications of the instrument.
12. Universalized online interface: USB2.0 interface, fast data transmission and convenient connection.
Specification
|
Model |
FSP-97 |
FSP-97pro |
FSP-97xp |
|
Detection sensitivity (water Raman peak signal noise ratio) |
S/N ≥150 (P-P) |
S/N ≥200 (P-P) |
|
|
Excitation wavelength Bandwidth |
10nm |
2nm/5nm/10nm/20nm |
|
|
Emission wavelength Bandwidth |
10nm |
2nm/5nm/10nm/20nm |
|
|
Wavelength accuracy |
± 1.0nm |
± 1.0nm |
±0.4nm |
|
Wavelength repeatability |
≤0.5nm |
≤0.5nm |
≤0.2nm |
|
Light source |
150W automatic deodorizing xenon lamp (Hamamatsu, Japan) |
||
|
Optical system |
Double-grating monochromator automatic wavelength scanning with optical excitation double beam ratio monitoring |
||
|
Fluorescence Receiver |
Original photomultiplier (Hamamatsu, Japan) |
||
|
Excitation wavelength range |
200nm~900nm |
||
|
Emission wavelength range |
200nm~900nm |
||
|
Wavelength scanning speed |
10 positions, fastest 48000nm/min, fine scanning 15nm/min |
||
|
Measurement line |
≥0.995 |
||
|
Gain adjustment range |
1~17 position optional |
||
|
Integral Response time |
6 position options: 4s ~ 20ms |
||
|
Data output |
Microsoft (R) Excel format, bmp image format |
||
|
Data transmission |
USB2.0 Interface |
||
|
Light value range |
0.00-10000 |
||
|
Peak intensity Repeatability |
≤1.5% |
||
|
Power source |
220V / 50Hz, 110V / 60Hz |
||
|
Standard energy consumption |
200W |
||
|
Dimensions (mm) |
380×445×310 |
||
|
Weight |
GW 14kg, NW 12kg |
||
Standard Accessories
|
Item Name |
Qty |
|
Fluorescence spectrophotometer host |
1 pc |
|
Instruction Manual |
1 pc |
|
Product certificate |
1 copy |
|
Application reference material |
1 pc |
|
Software U disk |
1 pc |
|
10mm stone English color dish |
2 pcs |
|
Power cable |
1 pc |
|
USB cable data line |
1 pc |
|
Fused wire (2A and 5A) |
2 each |
|
Packing List |
1 pc |
|
Dustproof cover |
1 pc |
Optional accessories
|
Item name |
Function |
|
Single hole sample cell holder (standard) |
Conventional liquid fluorescence measurement |
|
Multipurpose fluorescent sample holder |
Multiple measuring attachment bases |
|
Multiplier filter |
Elimination of frequency doubling interference peaks in fluorescence measurements |
|
200μL microcentrifuge tube measurement accessories |
Centrifuge tube fluorescence measurement function |
|
Capillary micro sample measurement accessories |
Capillary micro sample measurement function |
|
Single hole sample cell adapter |
Combined with a multi-purpose fluorescent sample holder to form a conventional liquid fluorescence measurement and fluorescence reflection measurement function |
|
Membrane fluorescent sample measuring frame |
Combined with multi-purpose fluorescent sample holder to form fluorescence measurement and fluorescence reflection and transmission measurement function of conventional film samples |
|
Powdery fluorescent sample measuring rack |
Combined with multi-purpose fluorescent sample holder to form a fluorescence measurement function of conventional powder samples |
|
Sheathed sample cell holder |
Combined with multi-purpose fluorescent sample holder to form a fluorescent measurement function of the sheathed fluorescent sample cell |
|
Trace quartz four-pass cuvette |
Provides a small sample fluorescence measurement function |
![]()