Products
PRODUCTS DETAILS
Home > Products >
Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C

MOQ: 1 set
Price: Negotiable
Standard Packaging: Plywood packing
Delivery Period: 5~8 working days
Payment Method: L/C,T/T
Supply Capacity: 500 sets/month
Detail Information
Place of Origin
China
Brand Name
SHUOBODA
Certification
ISO/CE
Model Number
USP-1901P/C
Optical System:
1600 Lines/mm CT Type Optical Path Enhanced Double Beam UV-visible Spectrophotometer
Slit Bandwidth:
0.3/1/2/4/5nm (5 Steps Automatically Adjustable)
Wavelength Range:
190-1100 Nm
Wavelength Resolution:
0.1 Nm, Optical Focal Length 350mm
Wavelength Accuracy:
±0.1nm (@656.1nmD2, ±0.3nm (full Wavelength Range)) Actual Measurement ±0.2nm
Wavelength Repeatability:
≤0.2nm
Highlight:

Pharmacology UV Visible Spectrophotometer

,

Medicine UV Visible Spectrophotometer

Product Description

USP-1901C Double beam UV-visible spectrophotometer

 

Product introduction

USP-1901C/P Double beam UV-visible spectrophotometer can be used for scientific research in physics, chemistry, medicine, biology, pharmacology, geology and other disciplines. It is one of the important quality control instruments widely used in chemical industry, pharmaceuticals, metallurgy, light industry, materials, environmental protection, medical testing and other industries and analytical industries.

 Photometer mode: detect the absorbance and transmittance of samples at a fixed wavelength;

 Spectral scanning: analyze the maximum absorption peak height and maximum absorption peak position of unknown samples (blind samples);

Instrument features

1. Uniquely designed optical system, 1600 lines/mm high-performance long-life holographic grating, and imported high-performance receiver ensure that the instrument has excellent performance indicators.

2. Imported environmentally friendly deuterium lamp system, effectively reducing the inhalation of ozone;

3. Advanced control system, new generation true color touch LCD display, can monitor the lighting time of deuterium lamp and tungsten lamp in real time;

4. Socket-type deuterium lamp and tungsten lamp design, can save you the trouble of optical debugging after changing the lamp;

5. Large sample chamber, can accommodate 5-100mm cuvettes of various specifications;

6. Can directly send test results, print spectra and experimental data;

7. GLP self-identification function, can detect the wavelength accuracy and photometric accuracy of the instrument at any time according to needs, and issue a test report;

8. Powerful storage function, can save various types of data and spectra; memory 1T;

9. Standard GMP audit tracking workstation professional scanning software can realize a variety of powerful functions including photometric measurement, quantitative analysis (including standard curve function), full wavelength spectrum scanning, kinetic (time) scanning, multi-wavelength testing, etc., fully meet the diverse requirements of testing and unlimited data storage.

Instrument Interfaces

Time scan - kinetic measurement is also called time measurement. The user can measure the absorbance or transmittance of the sample solution at intervals (scanning intervals) within a certain scanning time range according to the sample set wavelength point, and can also convert the absorbance into concentration by inputting the concentration factor.

You can set a single wavelength absorbance or transmittance time scan to establish an absorbance (or transmittance)-time curve.

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 0 

Basic measurement: Input wavelength to test the sample content value at the wavelength, and input sample content to test unknown samples.

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 1 

Spectral scanning - the sample needs to draw an absorption peak within a certain wavelength, and automatically give the peaks and troughs of unknown samples (qualitative analysis).

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 2 Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 3

 

Multi-wavelength measurement - refers to the need to measure the absorbance / transmittance /concentration of a sample at multiple wavelengths

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 4 

Quantitative measurement - To conduct quantitative analysis of samples, multiple standard samples (more than two) can be used to establish a wavelength absorbance-concentration curve, and the concentration of unknown samples can be obtained from this curve.

Enter the known X, B values to measure the content of unknown samples.

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 5Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 6 

 

DNA protein measurement

Measurement scheme 1: 260nm 280nm

Measurement scheme 2: 260nm 230nm

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 7 

DNA/protein automatic measurement mainly measures absorbance at 260nm/280nm/230nm/320nm, and obtains DNA and protein concentrations according to the calculation formula.

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 8 

DNA protein measurement results

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 9 

Technical Specifications

Model

USP-1901P

USP-1901C

Optical system

1600 lines/mm CT type optical path Enhanced double beam UV-visible spectrophotometer

Slit bandwidth

0.3/1/2/4/5nm (5 steps automatically adjustable)

Wavelength range

190-1100 nm

Wavelength resolution

0.1 nm, Optical focal length 350mm

Data display

8-inch new generation true color touch LCD display (two-way operation: host + PC workstation)

320*240 LCD display (two-way operation: host + PC workstation)

Wavelength accuracy

±0.1nm (@656.1nmD2, ±0.3nm (full wavelength range)) Actual measurement ±0.2nm

Wavelength repeatability

0.2nm

Scanning speed

High, medium and low three gears optional  4100nm/min

Stray light

0.02%T (220nm Nal; 360nm NaNO2)

Photometric range

0-200%T, -0.301-6.0A, -9999-9999C

Photometric accuracy

±0.002A (0-0.5A), ±0.3%T (0-100%T)

Photometric repeatability

±0.001A (0-0.5A), ±0.15%T (0-100%T)

Baseline flatness

±0.0005A

Baseline drift

±0.003A/h

Photometric noise

±0.0003A (500nm, 0A, 2nm spectral bandwidth)

Data output

U disk data output, PDF. excel.

Language

English

Power supply

AC 90-240V 150W

Detector

Imported photomultiplier tube

Weight

25 kg

Dimensions

600*500*210mm

 

 

 Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 10Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 11

 

Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 12Double Beam UV Visible Spectrophotometer For Medicine Pharmacology USP-1901P/C 13 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sitemap |  Privacy Policy | China Good Quality Lab Test Instrument Supplier. Copyright © 2025 Shuoboda Instruments (Hunan) Co., Ltd. . All Rights Reserved.