Product introduction
The TOC-800E total organic carbon analyzer uses the high-temperature catalytic oxidation-NDIR detection principle to measure the total organic carbon concentration in water samples. It can detect water samples with TOC concentrations from 0.050ppm to 35000.0ppm. It has high sensitivity, accuracy and good stability.
TOC-800E total organic carbon analyzer is an instrument with simple structure. The main components are installed on the host computer. Before measurement, the instrument needs to connect the gas line and prepare reagents. The instrument is controlled by special software installed on an embedded microcomputer or an external computer to perform data processing such as measurement, calibration, and printing.
Application
Ø Tap water, surface water, river, lake water
Ø Domestic sewage, industrial wastewater
Ø Chemical water (cleaning water, cooling water, recycled water, etc.)
Ø Laboratory research
Working principle
The sample is fully burned and decomposed into carbon dioxide and water by the high-performance oxidation catalyst in the combustion furnace. The water vapor is removed after being cooled by the condenser. The carbon dioxide is measured by a non-dispersive infrared detector (NDIR) to determine the total organic carbon in the sample. The content measured; the inorganic carbon in the sample is decomposed into carbon dioxide and water by an acid reagent, and the water vapor is removed after being cooled by a condenser, and the carbon dioxide is measured with a non-dispersive infrared detector (NDIR), thereby determining the content of the total inorganic carbon TIC in the sample: Total organic carbon TOC=TC-TIC.
Standards
International standard ISO8245;
National environmental protection standard HJ501-2009 of the People's Republic of China;
National Metrology Verification Regulations of the People's Republic of China JJG 821-2005
Features
1. High-resolution 10.4-inch touch screen, humanized interface, simple and convenient operation
2. Three-tube electronic condensation and dehydration technology ensures the dehydration efficiency of the entire system
3. Highly reflective gold-plated gas chamber, highly concentrated infrared light source and highly sensitive infrared detector ensure excellent NDIR performance; measuring ppb level data has sufficient sensitivity and accuracy
4. The detection curve is visible in real time, more intuitive
5. Real-time self-monitoring of temperature, pressure, and flow at multiple locations
6. The furnace heating adopts multiple protections. Overheating can automatically cut off the heating to improve product safety performance.
7. 64G hardware memory can store massive data for a long time and make it easy to query, and can query by time period
8. With password protection function
Technical advantages
1. The maximum temperature of the combustion furnace can reach 1300℃, which is much higher than 680℃, which greatly increases the oxidation efficiency, meets the detection requirements of almost all substances, and improves the detection accuracy and stability.
2. Different catalysts (such as CeO, Pt, CuO) and different temperatures can be selected according to the detection requirements of the sample, providing a full range of experimental conditions and making the detection more flexible.
3. Automatic injection of liquid samples saves manpower and time; the precision electromagnetic metering pump ensures the accuracy and stability of the injection volume, the continuous and uniform speed of injection, and avoids the fluctuation of test results due to individual operating differences; At the same time, the non-manual injection sampling method can reduce the contact between the human body and liquid, avoid human body injury, and improve safety.
4. The inorganic carbon reaction cell is designed with a heating device, which eliminates the tailing of sample peaks and shortens the sample measurement time.
5. A solid sampler can be configured to inject solid samples (soil, sludge, etc.) by boat, with a wide range of applications.
6. An automatic sampler is optional to achieve unattended operation, saving manpower and time.
Technical parameters
|
TOC-800E total organic carbon analyzer |
|
|
Test items |
TC,IC,TOC,NPOC |
|
Measuring principle |
High temperature oxidation-NDIR detection principle |
|
TOC detection range |
0.050~35000mg/L |
|
TOC detection accuracy |
0.050mg/L |
|
Salt tolerance |
100g/L |
|
Furnace temperature |
1300℃ |
|
TOC accuracy error |
≤±5% |
|
Sample volume |
20~1000µl |
|
Analysis time |
3~8min |
|
repeatability error |
≤3% |
|
Zero drift |
±2%/D |
|
Range drift |
±2%/D |
|
Test Conditions |
Acid Reagent: Phosphoric Acid Solution Carrier gas: high-purity oxygen (≥99.999%) |
|
Ambient temperature |
0-60℃ (temperature change within ±5℃/d) |
|
Relative humidity |
≤90%RH |
|
Power supply |
220V AC≤±10% 50Hz |
|
Power |
800W |
|
Size |
60cm×46cm×49cm |
|
Weight |
50kg |
Measurement software
Software meets GMP computer system verification:
Electronic signature
1) Log in through username and password, which are unique.
2) Passwords have length requirements to improve security.
3) It has a manual screen lock function to ensure the uniqueness and safety of the operation.
Permission management
1) Multi-level permission settings.
2) Administrators can grant different permissions to other operators to ensure that personnel only have permissions equivalent to their job functions.
Data integrity
1) It has an audit trail function and cannot be turned off.
2) All test results are saved and cannot be modified or deleted.
3) All operations are recorded (as long as the person entering has traces).
4) If the detection method is modified, the modified parameters will be recorded.
5) Data can be exported for backup to protect stored data for future calls.
|
|
Create a new user interface: Administrators can grant different permissions to other operators to ensure that personnel only have permissions equivalent to their job functions. |
|
|
Testing interface: The detection curve is visible in real time, which is more intuitive Automatic average calculation |
|
|
Curve fitting interface: Automatically fit curves, calculate formulas, and tie them to corresponding methods. You can also manually add records and fit curves. |
|
|
Audit trail: 1) Cannot be closed. 2) All operations are recorded (as long as the person entering has traces). |
Main parts configuration list
|
Name |
Description |
Origin |
|
The electromagnetic valve |
200kpa diameter 1.6mm |
Japan |
|
Peristaltic pump |
60ml/min reduction DC motor |
China |
|
Thermostat |
Accuracy: 0.1℃; Electric shock life: 1*105 times; |
China |
|
Micropump |
Usage environment: 0-50℃ ≤85% |
USA |
|
Dryer |
Delivery volume: 20μl per time; Accuracy: 1%; |
USA |
|
Burner |
Diaphragm material: PEEK |
China |
|
NDIR |
0-1000ml/min |
Germany |
Consumables list
|
Item Name |
Specification |
Unit |
|
quartz wool |
1-3μm |
g |
|
Platinum alumina catalyst |
Platinum content 0.5% |
g |
|
Combustion tube |
/ |
pc |
|
Halogen removal pipe |
/ |
pc |
|
quartz plate |
15g |
bag |
|
filter |
/ |
ea |
|
O-ring |
/ |
pc |
|
vial |
100ml |
ea |
|
acid bottle |
100ml |
ea |
|
PTFE connector |
6 to 3 |
ea |
|
Injection nut |
PEEK |
ea |
|
Air line nut |
PTFE |
ea |
|
Thumb screws |
M5 |
ea |
|
Connecting pipe |
3.2*1.6mm |
meter |
|
power cable |
/ |
pc |
|
software |
V1.0 |
set |
|
User manual |
/ |
pc |
|
Certificate |
/ |
pc |
Autosampler for water
![]()
Technical Features:
1. 24 sampling bottles to meet the detection of daily water samples.
2. It is used online with the TOC analyzer, and the automatic sampler is controlled by the TOC analyzer to change samples, so that it is fully automatic and unattended, saving manpower and material resources.
3. The operation is stable and reliable, and the position control of the sampling needle is precise.
4. Touch screen design, easy and convenient operation.
Sampler for Solid
![]()
Features:
1. Maximum injection volume 100mg
2. Electronically cooled sampling boat, multi-level sampling speed is optional, to meet the needs of different samples
Application range:
1. Solid, semi-solid and liquid polymers
2. Particulate sample
3. rocks, agricultural soil
4. Wastewater sludge, mud, sediments from estuaries, lakes and rivers
Adequate Supply
![]()
![]()