| MOQ: | 1 |
| Price: | Negotiable |
| Standard Packaging: | Plywood packing |
| Delivery Period: | 5~8 working days |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 500 sets/month |
Application Area
Ø Pharmaceutical industry
Ø Medical device industry
Ø Food and beverage industry
Ø Environmental protection industry
Product Features
1. The proprietary signal processing system boasts significant advantages such as online setting, real-time monitoring, self-calibration, and flow rate control, ensuring superior instrument performance.
2. The instrument employs a low-voltage electrical design for safe operation.
3. Different control temperatures are set according to the different properties of various samples to ensure complete sample digestion and more accurate and reliable measurement data.
4. Adjusting the cooling module power based on the sample injection volume enhances the overall system's dehydration efficiency, ensuring the dryness of the gas entering the detector.
5. The development and application of real-time monitoring software continuously monitors the instrument's operating status, comparing measured parameters with set parameters. If the critical setting is exceeded, the system... 6. Automatic alarm and handling methods provided;
7. Utilizes an automatic leak detection control system to monitor gas flow in real time, eliminating misoperation, comprehensively improving instrument performance, and ensuring operator and instrument safety;
8. The application of flow rate control signal processing technology shields the effects of flow rate fluctuations, ensuring stable and accurate readings;
9. The TIC reaction cell integrates heating, cooling, dehydration, and liquid level monitoring, simplifying gas and liquid flow paths, saving significant analysis time, and widening the detection limit;
10. The TOC detector uses a 24-bit digital solution, expanding the monitoring range, while the control system uses 32-bit signal processing technology, improving instrument performance;
Technical parameters
|
TOC-160 total organic carbon analyzer |
|
|
Detector |
NDIR |
|
Parameters |
TC, TIC, TOC, NPOC |
|
Digestion Mode |
UV / persulfate oxidation |
|
Operation Mode |
PC Control |
|
Application |
Liquid Sample, Gas Sample |
|
Gas Requirement |
Oxygen, Nitrogen ≥ 99.995% |
|
Measurement Range |
0-1000mg/l(can expanded) |
|
Detection Limit |
50μg/l |
|
Repeatability |
3% |
|
Maximum Salinity |
85g/l |
|
Power |
100-260VAC |
|
Size(mm) |
430*455*440 |
Adequate Supply
![]()
![]()