Introduction
DP-JS-2C Freezing force meter is a mainstream classic model. The measurement accuracy is 0.1g. The display screen is upgraded to a high-definition touch screen to provide automatic zero-point drift correction. For the first time, it is equipped with a freezing intensity measurement accuracy verification measurement program (measurable and correctable).
System Configuration
1. DP-JS-2C freezing force meter (accuracy 0.1g) 1 set
2. Cylindrical probe: diameter 12.700±0.010mm (bottom edge clear corner) 1 set
3. DP-HW-3A precision constant temperature cold water tank (food grade thickened stainless steel liner) 1 set
4. Temperature range: 3°C ~65°C
5. Temperature accuracy: <±0.1°C
6. Can display set temperature and real-time temperature
7. DP-ZL-3A Refrigerator (can work continuously for more than 72 hours) (stainless steel evaporator)
8. Freeze bottle (capacity=150ml inner diameter=59mm height=85mm) 16 sets
9. Disc retractable abutment 1 set
Applicable standards:
Ø "Chinese Pharmacopoeia" 2020 Edition
Ø Comply with current Chinese GMP regulations.
Ø National Standard "Food Additive Gelatin" GB6783-2013
Ø National Standard "Medicinal Gelatin Hard Capsules" GB13731
Ø Light industry standard "Edible Gelatin" QB/T4087-2010
Main technical indicators and characteristics
1. Instrument screen display features: 5-inch high-definition touch screen, interactive intelligent control.
2. Easy to control, just press the "start button", and all parameters such as peak Bloom g, final value Bloom g, mean Bloom g, penetration depth, standard deviation, and cumulative number of measurements will be displayed.
3. Freeze strength measurement accuracy verification measurement: The instrument is equipped with a standard measurement operation program, which can automatically read and display the meter based on the detection of 5 consecutive standard samples.
4. Quantitative data can be used to directly determine whether it is qualified or out of tolerance. Verification measurement results are printed in real time.
5. In order to adapt to different sample properties, the system provides a full range of preset measurement parameters: trigger point, deformation amount, measurement rate, creep characteristic retention time, number of continuous cycle measurements.
6. The instrument is equipped with a high-quality shock-absorbing coupling structure, and the measurement operation is vibration-free and noise-free.
7. Up and down displacement limit distance protection, force sensing element overload protection, measurement data protection
freezing force measurement range: 0~2000 Bloomg
8. Measurement and analysis accuracy: 0.1g
9. Freezing force measurement accuracy: ≤±0.1%
10. Deformation displacement range (arbitrarily set sampling depth): 0~75mm
11. Displacement analysis accuracy: 0.01mm (real-time display)
12. Conventional measurement rate displacement accuracy error: ≤±0.05mm
13. High-speed measurement rate displacement accuracy error: ≤±0.1mm
14. Measuring speed range: 0.1mm/s~3mm/s (stepless speed adjustment can make the measurement process easier and the measurement results more accurate)
15. Speed analysis accuracy: 01mm/s
16. Speed travel error: ≤0.1% (set speed)
17. The instrument provides five measurement modes:
18. Bloom-freezing strength test: real-time peak load, peak deformation, final load, peak average, standard deviation, cumulative number of measurements.
19. Normal-single compression test: real-time load force, positive peak, peak deformation, negative peak, final load, duration.
20. Hold Time-Compression hold test: peak load, peak deformation, final load, real-time countdown.
21. Cycle Count-Multiple compression tests: maximum peak, minimum peak, peak average, last peak, standard deviation, remaining times
22. Freeze intensity measurement accuracy verification measurement: The instrument automatically measures the measurement accuracy and automatically determines whether it is out of tolerance. If there is any deviation, it can be automatically corrected by the system.
23. Measurement units (Bloom g, g, N) can be switched with one click
24. Output: RS232 serial printing interface. USB access module can be added