BD-D5453-021Z fluorescence sulfur content tester 

Quantité Minimale De Commande: 1 ensemble
Prix: Négociable
Emballage Standard: Emballage en contreplaqué
Délai De Livraison: 5~8 jours ouvrables
Mode De Paiement: LC, T/T
Capacité D'approvisionnement: 500 ensembles/mois
Informations détaillées
Lieu d'origine
Chine
Nom de marque
SHUOBODA
Certification
ISO/CE
Numéro de modèle
BD-D5453-021Z
Plage de mesure:
0,1 ppm ~ 10 000 ppm
Abaissez la limite de détection:
2 ng
États d’échantillon mesurables:
liquide, gaz (le client choisit un échantillonneur de liquide).
Plage de contrôle de la température:
TA ~ 1300 ℃
Précision du contrôle de la température:
± 2 ℃
Alimentation:
AC220V ± 10%
Mettre en évidence:

Sulfur content tester

,

BD-D5453-021Z sulfur content tester

,

Fluorescence Sulfur Content Tester

Description du produit
BD-D5453-021Z Fluorescence Sulfur Content Tester
Product Overview

The BD-D5453-021Z fluorescence sulfur content tester utilizes pulsed ultraviolet fluorescence analysis method for precise sulfur content measurement in petroleum products, meeting national V and higher standard oil sulfur content detection requirements.

Applicable Standards

ASTM D5453, D6667, D7183, GB/T17930, GB/T11060, SH/T 0689, and related international standards.

Performance Characteristics
  • Advanced pulsed ultraviolet fluorescence analysis method with lower detection limit and higher accuracy
  • Windows Chinese operating platform with intuitive human-machine dialogue interface
  • Computer-controlled analysis process with data processing and real-time status display
  • Software stores 5,000 sample data with historical data query and graphical playback capabilities
  • International circuit design with imported components for reduced noise and enhanced sensitivity
  • Core components including membrane dryers, filters, xenon lamps, and photomultiplier tubes imported from US, Japan, and Europe
  • Premium imported heating furnace wire with extended service life and automatic over-temperature protection
  • Advanced double anti-leakage reaction chamber design for improved sensitivity and repeatability
  • Fast analysis speed (3-4 minutes per sample) with excellent precision and stability
  • Single-point calibration with adjustable high pressure, eliminating need for standard curve recalibration
  • Calibrated with US and Japanese standard samples for superior measurement accuracy
  • Open LIMS database management system for efficient data retrieval and management
Technical Specifications
Parameter Specification
Measurement Range 0.1 ppm - 10,000 ppm
Lower Detection Limit 2 ng
Sample States Liquid, Gas (with optional liquid sampler)
Temperature Control Range Room Temperature - 1300°C
Temperature Control Accuracy ±2°C
Repeatability Error 0.1-1.0 ppm: <±0.1 ppm
1-10 ppm: <10%
>10 ppm: <5%
Baseline Drift <2 μV/72h
Standard Reagents Sulfur standard 100 mg/L, 300 mg/L, 500 mg/L isooctane
Gas Requirements Argon: ≥99.995%
Oxygen: ≥99.99%
Host Dimensions 420 × 400 × 530 mm
Power Supply AC220V ±10%
Power Consumption 1500W
Temperature Controller 500 × 400 × 530 mm
Cooling Method Air Cooling
Standard Configuration

Complete system includes host computer (data acquisition and control system), cracking furnace, automatic sampler, computer with operating software, and printer.