| MOQ: | 1 set |
| Price: | Negotiable |
| Standard Packaging: | Plywood packing |
| Delivery Period: | 5~8 working days |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 500 sets/month |
Main features and software functions
1. Excellent optical systems, advanced control system: to ensure accurate positioning, good signal-to-background ratio
2. Imported key components: ensure instrument accuracy and sensitivity;
3. Minimum Matrix effect: 99% of the sample without matrix separation;
4. Wide measuring range: analysis from Ultra micro to constant;
5. Multiple elements analysis: 72 kinds of metal elements and some non-metallic elements can be analyzed,;
6. Can do qualitative or quantitative analysis;
7. Convenient analysis software: Based on the Windows XP platform ,the third generation of Chinese or English operating software, making it easier to operate easily, without having to install, software can be used directly, the data processing system to provide a variety of functions, output data can be arbitrarily selected and print.
Unique software advantages
|
Independent research and develop software with company logo |
Increase the standard addition method |
|
Based on windows XP, windows7 windows8, the third-generation multi-window analysis software in English and Chinese |
Integral ways: single-point fast, multi-point average, Gaussian curve |
|
multi-window and multitask can do simultaneously |
Test methods are: routine testing, normalization, coefficient calculation, standard addition method |
|
Default best analysis mode (no need modification or writting by the analysts), rapid scanning speed, support for laser printers, arbitrarily select the analysis result needed print, and can be printed at the same time. |
More user friendly (arranged by analysis step -from left to right - from top to bottom) |
|
Note: ICP as a large precision inorganic analytical instrument, its software operation and hardware of the instrument itself are the same important. The software without company logo is the earliest one , cannot be upgraded ,the operation speed is the slowest and few function. It is the theft of my company's software. |
|
Instrument overall performance index:
Wavelength range: 180-800nm (2400 raster) 180-500nm (3600 raster)
Resolution: in the 180-800nm full band, resolution can reach 0.006nm
Wavelength indication error and repeatability: Wavelength indication error ≤0.02nm, repeatability ≤0.003nm
Scanning pitches: 0.0004nm
Precision: RSD≤1.50%;
Stability: RSD≤2%
The detection limit (ie minimum measurement range): PPB level
Elements Analysis range: all elements except C, S and other lightweight non-metallic elements and part of the radioactive metallic element
The linear range: seven magnitude or more, and low self-priming effect
Analysis speed: scans 25 elements or more per minute
Certificates: National measurement equipment Class A certificate
The main parts detailed parameters
A radio frequency generator (RF)
|
Circuit Type |
Self-excited oscillation inductance feedback circuit |
Output Power |
800--1200W |
|
working frequency |
40.68MHz ± 0.05% |
Output power stability |
≤0.3% |
|
Frequency Stability |
<0.1% |
Leakage of electromagnetic fields emitted intensity |
30cm at E<1V / m |
Injection Device
|
Output working coil |
An inner diameter of 25mm, 3 turns |
|
Torches |
Three concentric outer diameters of 20mm quartz torch |
|
Coaxial sprayer |
outer diameter 6mm, special requirements can be customized |
|
Binocular-type spray chamber |
An outer diameter 34mm, special requirements can be customized |
|
Observation position |
vertical |
Argon gas flow meters and gas carrier pressure gauges Specifications
|
Plasma gas flow meter |
Auxiliary gas flow meter |
The gas carrier flow meter |
The carrier gas regulator valve |
Cooling water |
|
(100-1000)L/h (1.6-16L/min) |
(1-100)L/h (0.16-1.66L/min |
(10-100)L/h (0.16-1.66L/min) |
0-0.4Mpa)L/h
|
Water temperature:15-25℃ gas flow>5L/min water pressure>0.1Mpa cooling water:Resistivity>1MΩ |
Splitter
|
Light path |
Czerny-Turner |
Scan Step |
0.0004nm |
|
|
focal length |
1000mm |
Exit, entrance slit |
20μm×25μm |
|
|
Grating Specifications |
Ion etching holographic grating |
Groove density of 3600 lines / mm, groove area: 80 × 110mm (or groove density) |
Reflector Specifications (optional specifications) |
(78×105×16)mm |
|
|
2400 lines / mm, groove area: 80 × 110mm) |
lens |
φ30,1:1 imaging |
|
|
Reciprocal linear dispersion rate |
0.26nm/mm |
Reflector Specifications |
Concave
|
|
|
Resolution |
≤0.006nmFull band |
Splitter thermostat |
26℃±1℃ |
|
|
Scan wavelength range |
180-500nm,3600 Line / mm |
|
|
|
|
180-800nm,2400 Line / mm |
|
|
||
Metering Device
|
Photomultiplier tube specifications |
R212UH or R928 |
Sampling circuit
|
The use of foreign high-precision operational amplifier, the instrument sensitivity and accuracy greatly improved
|
|
Photomultiplier tube negative high voltage |
0-1000V, automatic adjustment, the stability of <0.05% |
Instruments data acquisition
|
Connected to the computer via serial port, thereby simplifying the circuit to make connection easier
|
|
Photomultiplier tube current measuring range |
10-12 ~ 10-4 A specifications optional |
Metering method
|
Single and multi-element sequential measurement, single-pass scan
|
|
Signal acquisition of V / F exchange |
1mV corresponds to 100Hz |
|
|
Customer Advantages
The manufacturer with most foreign customers (Russia, Vietnam, Mexico, South Africa, Zimbabwe, the United Arab Emirates), almost domestic testing institutions also choose our instruments (including: the 389 plant of 6th Aerospace Institute , Shenzhen Tyco testing Ltd., Academy of Architectural Sciences of Shenzhen, Guangzhou Building materials Research Institute, Inner Mongolia metallurgical Research Institute, China Institute of Agricultural Sciences, etc.), as well as some famous universities (Tsinghua University, Jiangxi University of Science, Xiamen Chemical Engineering, , Changsha Normal University and so on.
Starting from 2000, based on French JY company technology, specializing in the production ICP spectrometer. Having a group of professionals who engaged in the ICP spectrometer at the earliest in domestic, guaranteed by their rich working experience and enthusiasm, and improve services we are dedicated to provide high-precision, sensitivity and good stability of the plasma emission spectrometer product.
Packing List
|
Item |
Instrument Name |
Details |
Qty |
Unit |
|
1 |
Host |
ICP-8100 Inductively Coupled Plasma Emission Spectrometer Host |
1 |
set |
|
|
|
Czerny-Turner Ion e tched holographic grating |
1 |
set |
|
stepping motor |
1 |
set |
||
|
Photomultiplier tube PMT |
1 |
set |
||
|
electronic control system |
1 |
set |
||
|
Inductance feedback self-excited oscillation circuit |
1 |
set |
||
|
RF generator |
1 |
set |
||
|
atomizer |
2 |
pcs |
||
|
Spray chamber |
2 |
pcs |
||
|
Torque tube |
2 |
pcs |
||
|
Scanning spectrometer |
1 |
set |
||
|
Gas controller |
1 |
set |
||
|
Cooling air flow meter |
1 |
pcs |
||
|
Auxiliary gas flow meter |
1 |
pcs |
||
|
Carrier gas flow meter |
1 |
pcs |
||
|
Incident slit |
1 |
set |
||
|
Exit slit |
1 |
set |
||
|
Optical path control device |
1 |
set |
||
|
Main power cable |
1 |
pcs |
||
|
Main power socket |
1 |
pcs |
||
|
Sample operation platform |
1 |
set |
||
|
Flame observation window |
1 |
set |
||
|
Flame regulator |
1 |
set |
||
|
High-frequency power |
1 |
set |
||
|
Power protector |
1 |
set |
||
|
Optical path protection gas |
1 |
set |
||
|
2 |
Constant temperature system |
YT-1800 Intelligent temperature control cooling circulating water tank |
1 |
set |
|
Circulating water pump |
1 |
set |
||
|
Circulating water tank air conditioner |
1 |
set |
||
|
3 |
Analysis software |
ICP analysis software |
1 |
set |
|
Analytical methods: a complete set of methods used by the unit |
|
|
||
|
Analysis mode: software default optimal analysis mode, with the instrument diagnosis, spectrum analysis and several measurement methods and several kinds of integration mode, the unit is optional |
|
|
||
|
4 |
Computer |
Qitian M7150 |
1 |
set |
|
Display: 19 inch LCD |
1 |
set |
||
|
Other: sound card, network card, DVD CD-ROM |
1 |
set |
||
|
5 |
Printer |
HP1007Laser Printer |
1 |
set |
|
6 |
Exhaust system |
Axial flow fan |
1 |
set |