Automated Viscometer CAV 42 Aims to Boost Laboratory Throughput
Evenementen
Neem Contact Met Ons Op
Ms. Lisa
86--19083104120
Contact opnemen

Automated Viscometer CAV 42 Aims to Boost Laboratory Throughput

2026-10-25
Latest company blogs about Automated Viscometer CAV 42 Aims to Boost Laboratory Throughput

Laboratories that test petrochemicals, lubricants and related products are under pressure to maintain D445 compliance as sample volumes rise and staffing costs increase. Automated viscometry systems are being evaluated for their ability to deliver consistent measurements while reducing hands-on work. The CAV 4.2 is a dual-bath automated viscometer whose published specifications cover those laboratory requirements.

Core specifications

Technical specifications list a temperature range of 15°C to 150°C and a viscosity range of 0.5 to 10,000 mm²/s. The system can process up to 24 tests per hour and includes a preheating function that covers ambient temperature to 100°C.

Parameter Technical specification
Temperature range 15°C to 150°C
Viscosity range 0.5 to 10,000 mm²/s
Throughput Up to 24 tests per hour
Preheating function Ambient temperature to 100°C
Automation design and operational value

The unit uses a modular dual-bath design that provides redundancy for continuous testing and allows two independent baths to operate at different temperatures at the same time. For laboratories that frequently switch test temperatures, the configuration reduces equipment preparation time.

Independent sample handlers support unattended operation, while status indicators give operators a visual read on instrument activity without requiring constant presence at the unit.

Efficiency details
  • Selective preheating: Targeted zone preheating brings individual samples to the set temperature, shortening the wait before testing begins.
  • Independent sample processing: Dual sample handlers enable unattended operation and support reliable, stable test runs.
  • Flexible test methods: A single sample tray can hold multiple predefined or custom methods, streamlining workflow.
  • Status monitoring: Indicator lights let operators track instrument status without remaining at the bench.
Cost and maintenance profile

Beyond measurement accuracy, laboratory managers are weighing long-term operating costs. The CAV 4.2 includes design features intended to reduce solvent use, service calls and routine maintenance time.

  • Solvent consumption: A dedicated tubing design cuts solvent use and downstream waste disposal costs by more than 50 percent, according to the specifications.
  • Maintenance access: Operators can replace viscosity tubes in minutes, avoiding costly external service visits for minor faults.
  • Calibration control: A single-point temperature calibration approach reduces the frequency of repeated tube calibration and adds flexibility to testing.
  • Automated cleaning: An integrated sample vial cleaning and drying system saves manual cleaning time and lowers consumable use.

The combination of dual-bath automation, independent sample handling and lower solvent consumption is intended to help laboratories manage throughput and operating expenses without compromising D445 testing requirements.

Frequently Asked Questions
How does the dual-bath design improve efficiency in practice?
The dual-bath design allows the instrument to test at two different temperature points at the same time. For samples that require multi-temperature viscosity index determination, operators do not need to wait for one temperature test to finish before heating or cooling for the next, which shortens the overall testing cycle.
How can a laboratory scale up for high sample volumes?
A single CAV 4.2 unit can operate independently. For high-throughput laboratories, an external PC with supporting software can manage up to four CAV 4.2 units at once, providing centralized data management and process control.
Does replacing a viscosity tube require a specialized technician?
No. The design allows operators to replace viscosity tubes themselves in a few minutes without scheduling professional service personnel, which helps reduce equipment downtime and maintenance costs.
Bloggen
BLOG DETAILS
Automated Viscometer CAV 42 Aims to Boost Laboratory Throughput
2026-10-25
Latest company news about Automated Viscometer CAV 42 Aims to Boost Laboratory Throughput

Laboratories that test petrochemicals, lubricants and related products are under pressure to maintain D445 compliance as sample volumes rise and staffing costs increase. Automated viscometry systems are being evaluated for their ability to deliver consistent measurements while reducing hands-on work. The CAV 4.2 is a dual-bath automated viscometer whose published specifications cover those laboratory requirements.

Core specifications

Technical specifications list a temperature range of 15°C to 150°C and a viscosity range of 0.5 to 10,000 mm²/s. The system can process up to 24 tests per hour and includes a preheating function that covers ambient temperature to 100°C.

Parameter Technical specification
Temperature range 15°C to 150°C
Viscosity range 0.5 to 10,000 mm²/s
Throughput Up to 24 tests per hour
Preheating function Ambient temperature to 100°C
Automation design and operational value

The unit uses a modular dual-bath design that provides redundancy for continuous testing and allows two independent baths to operate at different temperatures at the same time. For laboratories that frequently switch test temperatures, the configuration reduces equipment preparation time.

Independent sample handlers support unattended operation, while status indicators give operators a visual read on instrument activity without requiring constant presence at the unit.

Efficiency details
  • Selective preheating: Targeted zone preheating brings individual samples to the set temperature, shortening the wait before testing begins.
  • Independent sample processing: Dual sample handlers enable unattended operation and support reliable, stable test runs.
  • Flexible test methods: A single sample tray can hold multiple predefined or custom methods, streamlining workflow.
  • Status monitoring: Indicator lights let operators track instrument status without remaining at the bench.
Cost and maintenance profile

Beyond measurement accuracy, laboratory managers are weighing long-term operating costs. The CAV 4.2 includes design features intended to reduce solvent use, service calls and routine maintenance time.

  • Solvent consumption: A dedicated tubing design cuts solvent use and downstream waste disposal costs by more than 50 percent, according to the specifications.
  • Maintenance access: Operators can replace viscosity tubes in minutes, avoiding costly external service visits for minor faults.
  • Calibration control: A single-point temperature calibration approach reduces the frequency of repeated tube calibration and adds flexibility to testing.
  • Automated cleaning: An integrated sample vial cleaning and drying system saves manual cleaning time and lowers consumable use.

The combination of dual-bath automation, independent sample handling and lower solvent consumption is intended to help laboratories manage throughput and operating expenses without compromising D445 testing requirements.

Frequently Asked Questions
How does the dual-bath design improve efficiency in practice?
The dual-bath design allows the instrument to test at two different temperature points at the same time. For samples that require multi-temperature viscosity index determination, operators do not need to wait for one temperature test to finish before heating or cooling for the next, which shortens the overall testing cycle.
How can a laboratory scale up for high sample volumes?
A single CAV 4.2 unit can operate independently. For high-throughput laboratories, an external PC with supporting software can manage up to four CAV 4.2 units at once, providing centralized data management and process control.
Does replacing a viscosity tube require a specialized technician?
No. The design allows operators to replace viscosity tubes themselves in a few minutes without scheduling professional service personnel, which helps reduce equipment downtime and maintenance costs.